Top Oximetery, Stethoscope, ECG, Fetal Doppler Monitors Distributor United States, USA,   
Order Tracking  My Account  
Shopping Cart | Checkout more
Items: 0
Total: US$0.00
Live Help Top Oximetery, Stethoscope, ECG, Fetal Doppler Monitors Distributor United States, USA, 
  Home » Pulse Oximeter » Finger Pulse Oximeter Parameters
Free Shipping on Everything.
Products
Baby Store
Drug Tests
Fetal Dopplers
Nebulizers
Peak Flow Meters
Pregnancy & Ovulation Tests
Pulse Oximeters
Respiratory Care
Thermometers
Purchase Order
Testimonials more
Great selection of products, great information/specs, found what I wanted, ordered it at a great pri...(read more)

Tim Beck
Information
Customer Service
Safe Shopping
Shipping & Returns
Privacy Notice
Conditions of Use
Contact Us
FAQ
Articles
New Articles
All Articles
Fetal Doppler (6)
Promotion
Thermometer and Flu (3)
Pulse Oximeter (11)
Peak Flow Meter (1)
Nebulizer (6)

Finger Pulse Oximeter Parameters

by ClinicalGuard.com Technical Team

Finger Pulse Oximeter Parameters - OctiveTech 300-series

1. Overview

This document contains an overview of suggested operating parameters for the OctiveTech series of Finger Pulse Oximeters (http://www.clinicalguard.com/digit-pulse-oximeters-c-25.html). This document is intended to be a guide only, and should not be used as a substitute for clinical diagnosis performed by a licensed practitioner.

2. Extended Specifications

Spo2 Measurements Pulse Rate
Range: 0% - 100%
Resolution: 1%
30-254 BPM
Resolution: ±1bpm
Accuracy: 80% - 99%, ±2% Accuracy: ±2bpm or ±2%
Accuracy: 70% - 79%, ±3% Accuracy: 0% - 69%, unspecified

3. Measurement Interpretation

This section contains a guideline on various levels of blood oxygen and heart rate that are within tolerable ranges.

3.1 Oxygen Saturation

Measurement Critical Notes
Spo2 > 95% N Normal healthy individual
Spo2 91% - 95% N Clinically acceptable, but low. Patient may be a smoker, or be unhealthy.
Spo2 70% - 90% Y Hypoxemia. Unhealthy and unsafe level.
Spo2 < 70% Y Extreme lack of oxygen, ischemic diseases may occur. The OctiveTech 300-series of Oximeters is not calibrated to detect readings lower than 70%.

3.2 Resting Pulse Rate

Measurement Critical Notes
PR <40 BMP Y Below healthy resting heart rates. OctiveTech 300-series does not detect pulse rates lower than 30BMP.
PR 40-60 BPM Y/N Resting heart rate for sleeping.
PR 60-100 BPM N Healthy adult resting heartrate.
PR 100 BPM – 220 BPM Y Acceptable if measured during exercise. Not acceptable if resting heartrate.
PR > 220 BPM Y Abnormally high heart rate. The OctiveTech 300-series does not detect heart rates > 254 BPM.

Disclaimer:
The information on this website aims to provide customers with relevant knowledge regarding our products. Under no circumstances should the information be used for therapeutic purposes. Customers must consult their doctors for the correct use of these information and products. ClinicalGuard.com is not responsible for any losses or accidents caused by the use of information on this website.

This article was published on Wednesday 25 April, 2007.
Products related to this article:
Handheld Pulse Oximeter OctiveTech 300AH
Handheld Pulse Oximeter OctiveTech 300AH
Handheld Pulse Oximeter OLED OctiveTech 300IH
Handheld Pulse Oximeter OLED OctiveTech 300IH
OLED Finger Pulse Oximeter OctiveTech 300D
OLED Finger Pulse Oximeter OctiveTech 300D
Finger Pulse Oximeter OctiveTech 300C
Finger Pulse Oximeter OctiveTech 300C
Finger Pulse Oximeter OctiveTech 300F
Finger Pulse Oximeter OctiveTech 300F
Customer Service | FAQ | Contact Us | Send us an Email | Online Chat | Shipping & Returns | Order Status
My Account | Recover Password | Conditions of Use | Privacy Notice | Safe Shopping | Featured Products
RSS | Blog | Affiliate Program | Testimonials | Green Campaign
Safe Shopping at ClinicalGuard.com Top Oximetery, Stethoscope, ECG, Fetal Doppler Monitors Distributor United States, USA, 
Copyright © 2010 ClinicalGuard.com